Posted Jan 9

I think battle born battery company is finished. wow. The root cause is that they tighten the power terminal bolts thru a sheet of ABS plastic that eventually gets hot and subsides. Now the bolt is loose because the plastic it's attached to is thinner. And to think, this is a premium battery at a premuim price.

1,760 views

Posted Jan 9

Any idiot with a beard and a wife with long hair can start a youtube channel in the genre of "off grid". The cuter the wife, the more popular the channel. Change my mind.

1,630 views

Posted Jan 9

Any idiot with a beard and a wife with long hair can start a youtube channel in the genre of "off grid". The cuter the wife, the more popular the channel. Change my mind.

1,580 views

Posted Jan 8

Off grid doorbell idea

1,690 views

Posted Jan 8

1,570 views

Posted Jan 8

https://youtube.com/shorts/fMTW8knS7iw

2,009 views

Posted Jan 8

I wired up 6 strings of panels to a PV busbar and then connected two MPPT chargers to that bus bar. Today, one of those units malfuctioned and let some magic smoke out. No worries, its a warranty claim. The issue is that since it was connected to the same solar panels as teh other unit, the other unit saw some shenanigans with the voltage from teh PV positve to the battery postive and decided it should "crowbar" the solar panels. So two different failures cascaded. I should NOT have connected two MPPT units to ONE set of solar panels. Lesson learned is each MPPT gets it's own set of dedicated solar panels. Ordinarily you can reset the crowbar in software but it didn't work this time. So two units down and two RMAs.

1,720 views

Posted Jan 8

Victron MPPT 250/100 feature.... There are several conditions where the victon MPPT will go in to what I'll call "panic mode". When it does this, it closes a latching relay across the PV inputs. This can be reset via the bluetooth app on your phone. It's a really cool feature because if you didn't anticipate the solar panel voltage going over 250v and one fine cold morning it does, then it will save itself by "crowbarring" the solar input. The other condition is if it detects a short circuit between the battery + and the PV +. So what happened today.... (next post).